| Building Element | BAL-12.5 and BAL-19 | BAL-29 | BAL-40 | BAL-FZ3 |
|---|---|---|---|---|
| Where attached structure separated from the building by a fire rated FRL 60/60/60 wall that extends to the underside of a non-combustible roof covering1 (refer to External fire rated walls) |
hySPAN LASERframe ALLseasons |
hySPAN LASERframe ALLseasons |
hySPAN LASERframe ALLseasons |
hySPAN LASERframe ALLseasons |
| Where the roof of an attached structure is separated from the roof space of the main building by a masonry veneer wall, 90mm thick | For the complete structure, refer to the individual building elements noting the roof covering must be non-combustible |
For the structure supporting the roof and it’s framing, refer to the individual building elements For roof framing hySPAN/ LASERframe lined on the underside with 6mm fibre-cement sheeting noting the roof covering must be non-combustible |
For the structure supporting the roof and it’s framing, refer to the individual building elements For roof framing hySPAN/ LASERframe lined on the underside with 6mm fibre-cement sheeting noting the roof covering must be non-combustible |
For the structure supporting the roof and it’s framing, refer to the individual building elements For roof framing hySPAN/ LASERframe lined on the underside with 6mm fibre-cement sheeting noting the roof covering must be non-combustible |
| Where the adjacent building is separated from the main building by at least 6 m2 |
hySPAN hyJOIST LASERframe ALLseasons |
hySPAN hyJOIST LASERframe ALLseasons |
hySPAN hyJOIST LASERframe ALLseasons |
hySPAN hyJOIST LASERframe ALLseasons |
1 For all other situations refer to the individual building elements
2 When not separated from the building by 6m or a fire rated wall, refer to individual guides
3 NSW requirements do not recognize BAL-FZ construction solutions from AS3959 2009. A BCA Alternative Solution is required for BAL-FZ construction in NSW.
July 2010 (2)